Pressure reducer unit

Article number: 02233

Introduction:

The pressure reducer unit includes pressure reducing valve device, high pressure tube, medium pressure tube, electical pressure gauge, alarm whistle, fast connector. High-pressure air can be converted into low-pressure air that is a safe breathing standard for the human body.

Features: Scientific design, safe decompression, selection of high quality stainless steel, anti-oxidation, flame retardant, impact resistance, pressure gauge 24 hours waterproof.

Software image and text block

Pressure reducing valve

Model: DSPR-1

Introduction:

The pressure reducing valve is a device that depressurizes the high-pressure gas to a constant output pressure of 0.8±0.2 MPa and supplies the gas to the supply valve. The pressure relief valve is mounted on the backrest and is linked to the cylinder valve by the connection nut hand-wheel.

The gas source output is divided into two parts: high pressure and low pressure. The high-pressure gas source gas is sent to the high pressure meter and residual gas alarm through the high pressure tube. After decompression, the low-pressure gas source is sent to the air supply valve through the medium pressure tube, and the low pressure end is provided with a safety valve in the crucible cavity. Pressure relief valve and medium pressure tube, high pressure tube connection are plug-in type, the tube can rotate freely.

Software image and text block

Medium pressure safety valve:

The medium pressure safety valve is the installation and protection device of the pressure reducing valve decompression function. It is installed in the cavity of the pressure reducing valve. When the pressure reducing valve is affected by certain factors, the medium pressure rises and the pressure in the chamber reaches 1.1-1.7 MPa. The medium pressure relief valve automatically opens and relieves pressure to ensure that the medium pressure tube and the gas supply valve are in normal operation.

Medium pressure tube

Introduction:

The medium pressure tube is an air output flexible conduit composed of a rubber tube and a quick connector. One end is connected to an gas supply valve, and the other end is connected to a pressure reducer. The connection method is a card-type connection, which can be quickly loaded and unloaded, and can also be freely rotated in the same plane.

Software image and text block

High pressure tube & Pressure gauge & Warning whistle

High pressure tube

The high-pressure tube is a pressure-resistant rubber tube, and it is responsible for delivering the high-pressure gas source to the high pressure meter and the residual gas alarm system.

High-pressure tube design combined with the front alarm system, at any time to see the remaining air in the cylinder, the bottle will automatically alarm when the pressure is lower than 5MPa.

Software image and text block

Electronic pressure gauge DSFSB-1

The combination of a high-voltage gauge and a residual alarm can both indicate the air supply pressure of the cylinder and give an audible alarm when the cylinder reaches the design approval pressure.

Both the pointer and the screen of the electronic pressure gauge can show the cylinder pressure. At the same time, the data is transmitted to the HUD via Bluetooth to light up. Effectively avoid delaying the rescue time by looking down at the pressure gauge and affecting attention.

Article number: 02061

Software image and text block

Alarm whistle DSJBQ-1

The gauge range is 0-40MPa, the working pressure of the cylinder is 27-30MPa and the alarm pressure 5-6MPa is marked with green and red areas, respectively. When the pressure of the cylinder drops to 5±0.5MPa, the residual gas alarm will emit a continuous sound of 90dB to remind the user that the gas source will be used up and it is necessary to evacuate the site as soon as possible. For a cylinder with a volume of more than 5L, the gas source for the cylinder can be used by the wearer for 5-8 minutes.

Article number: 02076

Software image and text block
Software - Sample 1 for three columns

download tech datas

Notice

1. At present, web page supports payment in 11 currencies. Please choose the corresponding currency before placing the order.

2. Not only supports bank wire transfers, but also supports online payment. At present, credit cards (VISA, MASTER CARD), Paypal, Alipay, Google payment, apple payment and other payment methods have been opened. We have opened different ways of payment according to local laws.

3.The price displayed on the webpage is the unit price of the product, excluding the tax rates of all countries. When placing an order, the system will default to add the tax rate of the country to which it belongs. For example, when placing an order with a mainland customer, it will add a 16% VAT.

4. At present, the global inventory established by DOSEEM has been relatively perfect, but in some less developed countries and regions, we will arrange shipments by modern processing. We will gradually improve, please be patient!

5. Because of the variety of products, customers can search for keywords (such as internal bar code, product model, product name) in the search box when ordering.

6. In order to prevent you from buying fake and inferior products, please place an order directly on our official website or ask an agent or distributor for purchase. At present, the company uses two-dimensional code anti-counterfeiting. After scanning the code, it can get a random bonus as a reward.